Touch screen control module
Downloadable data logging
One piece deep drawn seamless chamber
Free standing shelf system
Easy to clean
.........................................................................................................................................................
| :: |
Class leading 2000C sterilisation |
| :: |
Touch screen control system |
| :: |
Deep drawn seamless chamber |
| :: |
Fuill data logging (text & graphical) |
| :: |
Electro-polished chamber |
| :: |
190 litre capacity |
| :: |
Premium stainless steel |
| :: |
No fan (less risk of contamination) |
| :: |
Anti-bacterial biocide plant |
| |
| CONSTRUCTION |
| The new LEEC Culture Safe CO2 Incubator has a fully sealed, electro-polished, one-piece, deep drawn chamber, manufactured from the highest grade 316 stainless steel. The outer cabinet is manufactured from stainless steel, and has an anti-bacterial powder coat paint finish. This gives the incubator exceptional corrosion and contamination resistance. An inner glass viewing door closes positively onto an inert (no VOC’s) gasket and allows a clear view of the chamber contents without disturbing the internal atmosphere. The outer door has a magnetic gasket providing a good seal. A side access port allows temperature monitoring probes to be inserted safely into the incubator chamber. |
| |
| |
| UNIQUE HEATING |
| A new 6 sided direct heating system with high performance insulation ensure the highest standards in temperature control and stability. The independent outer door heater ensures that the inner glass door remains condensate free. |
|
|
| |
Touch 190 |
Touch 190S |
| External (Dimensions H x W x D mm) |
850 x 765 x 600 |
850 x 765 x 600 |
| Internal (Dimensions H x W x D mm) |
685 x 630 x 435 |
685 x 630 x 435 |
| Chamber Capacity (liters) |
190 |
190 |
| Shelves Included |
4 |
4 |
| Power Rating (watts) |
TBC |
TBC |
| Weight (kg) |
TBC |
TBC |
| Temperature Range |
At least 50C above ambient to +600C |
|
| Temperature Control |
Typically +- 0.10C at 370C |
|
| Temperature Variation |
Typically better than +- 0.20C at 370C |
|
| Temperature Recovery ( approx.) |
TBC |
TBC |
| Sterilisation |
n/a |
2000C hot air |
|
| |
|
ANTI-CONTAMINATION
We have designed this incubator to eliminate contamination inside the chamber. Features include fan-less air circulation, a crevice-free, electro-polished, one-piece chamber, HEPA filtered gas inlet and a market leading 200°C hot air sterilisation cycle. Externally, the paint contains an active anti-bacterial biocide. |
| |
CONTROL SYSTEM
The multi-function, PID touch screen module controls the temperature, CO2, and alarm functions (including low gas and power failure) and provides real time data logging in graphical and text format. The module also allows data to be downloaded. An independent safety cut out disconnects the heating system should an over temperature condition occur. The module can be password protected too, stopping any unauthorised adjustment to the control systems. |
| |
|
LEEC CO2 Incubators are covered by a 2 year warranty.
|
 |
| Note: For more information please visit – www.leec.co.uk |
| |
|