Purifier Logic Class II Biological Safety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment with lots of exclusive unmatchable features such as :
| » |
Logically controlling airflow using ECM technology which precisely monitors and controls airflow through the cabinet without the need for sensors. |
| » |
Innovative Line-of-sight information center display, showing the unique “Filter Remaining” bar graph and other important parameters of cabinet. |
| » |
Logical ergonomics like :
- Fully-closing, 10° angled counterbalanced tempered safety glass sash.
- Unique patented Curved stainless steel inlet grille to support user’s forearms to avoid uncomfortable, hard-to-clean armrests.
- Bright, 90-100 foot-candle, glare-free fluorescent lighting.
|
| » |
Supply and Exhaust 99.99% HEPA filter. Option of 99.999% ULPA filters also available. |
| » |
Intelligent Smart-Start™ System and Night-Smart™ System. |
| » |
All cabinets are NSF International certified and ETL listed with CE conformity marking in all 230V models. |
|
* Sizes available in 3ft, 4ft, 5ft and 6ft
Class II, Type A2 Biological Safety Cabinets
During operation, room air is drawn into the inlet grille at the work access opening and through a supply HEPA filter. Approximately 70% of the HEPA-filtered air is circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is discharged.
These biohazard cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-ducted, these biological safety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research. Other appropriate applications include work with antineoplastic drugs, genetic material, carcinogens, allergens and additional substances that generate hazardous airborne particulates.
* Sizes available in 4ft and 6ft
Class II, Type B2 Biological Safety Cabinets
These biological safety cabinets are designed to be hard ducted to the outside. During operation, room air is drawn into the top of the cabinet through a supply HEPA filter. This filtered air flows downward through the work area. Room air is also drawn into the inlet grille located at the work access opening. All of the contaminated air passes through the exhaust HEPA filter. A dedicated exhaust system and remote blower discharge 100% of the filtered exhaust air out of the laboratory. Since none of the air is recirculated, these biohazard cabinets may be used for work with agents treated with volatile toxic chemicals and radionuclides. The ductwork and remote blower are required.

* stands available in 3ft, 4ft, 5ft and 6ft sizes
Base stands
Labconco base stands are ADA complaint and meets NSF standards for stability and construction. They provide sturdy support for loads atleast 455 kgs. Various types of stands available for users to select based on the requirement.
|