Home » Products » Instrumentation » Biological Safety Cabinets
Biological Safety Cabinets - Labconco Corporation, USA – Class II, Type A2 & B2
Labconco : Biogentek.com
We've Come A Long Way
Biogentek.com Biogentek.com Biogentek.com Biogentek.com
1976 1984 1995 2000
The latest Model ' Logic ' follows these since 2007
Labconco : Biogentek.com
All International Certifications
Biogentek.com
Biogentek.com
Biogentek.com
 
Did you care to check from the NSF Website that the particular Model of BioSafety Cabinets that you are buying is NSF-49 Certified or not ??? NSF has a complete listing of all models with exact catalogue No.’s ( ALL MAKES ) which it certifies. Kindly read on ...
If Not, Please do so !!  
Don’t get carried away by statements such as “ meeting to “ or Complying “ or “ compliant with “ NSF – 49 – It simply has no relevance !!
Also Please do ensure that the particular model that you are buying is NSF-49 Certified for 230 Volts / 50 Hz or not !!
Labconco BioSafety Cabinets Class II, Type A2 or B2 are truly the originals, NSF – 49 Certified Since 1976 ( All models clearly listed on the NSF website, as also the operating voltages )
Kindly look at the options below :


 
Purifier Logic Class II Type A2 & B2 Biological Safety Cabinets
HEPA Filtered Biological Safety Cabinets, Enclosures and Clean Benches®

Labconco manufactures a variety of ventilated enclosures that use 99.99% efficient HEPA filtration to provide personnel, environmental and/or product protection.

Purifier Logic Class II Type A2 & B2 Biological Safety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment.


Some important features :

   NSF 49 certified for 230 Volt, 50 Hz.
Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph
   
Latest technology blower motor which consumes less energy (240 watts), generates less heat (67 BTU/ Hour), noise level 62 dBA & has long motor life i.e. 50,000 Hours. It has a high torque which ensures longer filter life.
   
Automatically compensate upto 200% filter load without the need of any manual intervention.
   
System automatically compensates for low and high voltage and maintains proper blower speed.
   
Supply and exhaust 99.99% efficient HEPA filters / 99.999% ULPA Filters as per users choice.
   
Electronic security lock RS 232 Port
   
Sound level : 62 dBA
Measured as per NSF standards i.e. 15” above the work surface and 12” in front of the unit. EN requires a measurement be taken 1 meter in front of the unit.


.........................................................................................................................................................

Biological Safety cabinet Class II type A2 available in 3’, 4’, 5’ and 6’ widths

Biological Safety cabinet Class II type B2 available in 4’ and 6’ widths


Options :

 ULPA filters 99.999% efficient
 Base Stand
 Service fixture for gas
 Inflow & Downflow sensor kit
 Turn Table
 Logic cart
 Cord Management System
 Interior shelf
 Remote Blower

Patented Filter Monitoring System : Biogentek.com

Patented Filter Monitoring System : Biogentek.com

Patented Filter Monitoring System
Patented Filter Monitoring System
 
Event Timer : Biogentek.com Complete Protection for the user : Biogentek.com
Event Timer Complete Protection for the user
Note: For more information please visit - www.labconco.com
 