All International Certifications |
 |
|
 |
|
 |
|
| |
| Did you care to check from the NSF Website that the particular Model of BioSafety Cabinets that you are buying is NSF-49 Certified or not ??? NSF has a complete listing of all models with exact catalogue No.’s ( ALL MAKES ) which it certifies. Kindly read on ... |
| If Not, Please do so !! |
|
Don’t get carried away by statements such as “ meeting to “ or Complying “ or “ compliant with “ NSF – 49 – It simply has no relevance !!
Also Please do ensure that the particular model that you are buying is NSF-49 Certified for 230 Volts / 50 Hz or not !! |
| Labconco BioSafety Cabinets Class II, Type A2 or B2 are truly the originals, NSF – 49 Certified Since 1976 ( All models clearly listed on the NSF website, as also the operating voltages ) |
Kindly look at the options below :
|
|
| Purifier Logic Class II Type A2 & B2 Biological Safety Cabinets |
HEPA Filtered Biological Safety Cabinets, Enclosures and Clean Benches®
Labconco manufactures a variety of ventilated enclosures that use 99.99% efficient HEPA filtration to provide personnel, environmental and/or product protection.
Purifier Logic Class II Type A2 & B2 Biological Safety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment.
Some important features :
| |
NSF 49 certified for 230 Volt, 50 Hz. |
| |
Interior-mounted, line-of-sight LCD information center with "Filter Life Remaining" bar graph |
| |
|
| |
Latest technology blower motor which consumes less energy (240 watts), generates less heat (67 BTU/ Hour), noise level 62 dBA & has long motor life i.e. 50,000 Hours. It has a high torque which ensures longer filter life. |
| |
|
| |
Automatically compensate upto 200% filter load without the need of any manual intervention. |
| |
|
| |
System automatically compensates for low and high voltage and maintains proper blower speed. |
| |
|
| |
Supply and exhaust 99.99% efficient HEPA filters / 99.999% ULPA Filters as per users choice. |
| |
|
| |
Electronic security lock RS 232 Port |
| |
|
| |
Sound level : 62 dBA
Measured as per NSF standards i.e. 15” above the work surface and 12” in front of the unit. EN requires a measurement be taken 1 meter in front of the unit. |
.........................................................................................................................................................
Biological Safety cabinet Class II type A2 available in 3’, 4’, 5’ and 6’ widths
Biological Safety cabinet Class II type B2 available in 4’ and 6’ widths
Options :
ULPA filters 99.999% efficient
Base Stand
Service fixture for gas
Inflow & Downflow sensor kit
Turn Table
Logic cart
Cord Management System
Interior shelf
Remote Blower
|
|
| Note: For more information please visit - www.labconco.com |
| |
|